"Run-time Error 5: Invalid procedure call or argument" when starting FRx
Entry Type: Informational
Product: Sage MAS 500 ERP
Application: FRx
Version Reported: 6.74
Subject:
"Run-time Error 5: Invalid procedure call or argument" appears when starting FRx.
Possible Resolutions:
- Apply the latest FRx service pack.
- The data source may be damaged.
- Create a new data source name (DSN). For more information on creating a DSN, see How to access a different database from FRx.
- Configure FRx to run on the new DSN.
- Reregister the system files:
- In the root folder where FRx is installed, browse to ..\FRx Software\FRx 6.7\.
- Double-click FRxReg67.cmd to reregisters the files.
- The system database file (FRxSys32.mdb) may be damaged. Compact the database. For more information, see How to compact the specification set or system database.
To locate the database file, browse to ..\FRx Software\FRx 6.7\SysData\.
If the above steps do not resolve the issue, contact Customer Support to perform a manual repair and compact the database.