INFORMATIONAL ** THIS INFORMATION HAS NOT BEEN VERIFIED **
"FRx32OFSI Main.(CheckOFSIconnection): 8900 Invalid or missing Data Source Name", occurs when setting the company as default in FRx
Entry Type: Informational
Product: FRx
Application: FRx
Version Reported: 6.7
Subject:
"FRx32OFSI Main.(CheckOFSIconnection): 8900 Invalid or missing Data Source Name", occurs when setting the company as default in FRx
Possible Resolution:
Create a new DSN for FRx version 6.5 or higher.
- In FRx, select Company, Information, then highlight the applicable Company. On the System Specific Information tab and click Define button.
- Select Add on the User DSN tab.
- Select MAS 90 4.0 ODBC Driver (Sage MAS90 32-Bit ODBC Driver if using 4.05 or lower)
- Click Finish.
- On the Basic tab, enter a new Data Source Name and Description (i.e. FRx).
- In the Database Directory field, enter the path to the .\MAS90\ directory.
- On the Options tab, enter the following:
- In the Prefix for data files field, enter the path to .\MAS90\soa\ directory. Note: Must have \ backslash at the end of the path.
- In the Path to View DLL field, enter the path to the .\MAS90\Home\ directory. Note: Must have \ backslash at the end of the path.
- Check the boxes for Dirty Read and Burst mode.
- Select Apply
- Select OK twice
- In FRx, select the Data Source created above from the Data Source Name list.
- Click Set as Default
- Click Save.