INFORMATIONAL ** THIS INFORMATION HAS NOT BEEN VERIFIED **
"Runtime Error 339 Component 'THREED32.OCX' or one of its dependencies not correctly registered: a file is missing or invalid, that file is located in the ...system32\winnt folder", occurs when launching FRx.
Entry Type: Informational
Product: FRx
Application: FRx Desktop
Version Reported: 6.74
Subject:
"Runtime Error 339 Component 'THREED32.OCX' or one of its dependencies not correctly registered: a file is missing or invalid. that file is located in the ...system32\winnt folder", occurs when launching FRx.
Possible Resolution:
The THREED32.ocx file is missing, damaged, or is not registered properly. To resolve this issue, perform the following:
-
Close FRx.
-
From Windows Explorer, browse to the FRx program directory, and locate the THREED32.ocx file.
-
If the file exists, manually register the file.
-
If the file is missing, perform the following:
- Close FRx on all workstations.
- Copy the file from a different workstation, and paste into the affect workstation's FRx program directory.
- Manually register the file.