"Runtime Error 5: Invalid procedure call or argument" when changing the path to the ..\Sysdata\ directory

Entry Type: Informational

Product: FRx

Application: FRx Desktop

Version Reported: 6.7

Subject:

"Runtime Error 5: Invalid procedure call or argument" occurs when changing the path to the ..\Sysdata\ directory.

Possible Resolution:

There is no default company selected in FRx. To resolve this issue, set the FW company as default.

  1. In FRx, select Company / Select Default.
  2. Select "FW" from the list of companies, and click 'OK'.
  3. Change the path to the ..\Sysdata\ directory.