"Run-time error 6: Overflow" when generating a report in FRx
Entry Type: Program Issue
Product: FRx
Application: FRx Desktop
Version Reported: 6.5.152
Status:
Resolved with Service Pack 6.5.199
Subject:
"Run-time error 6: Overflow" occurs when generating a report in FRx. This error occurs when there are more than 13 columns and 50 row codes.
Steps to Duplicate:
FRx for Sage MAS 90 and 200
- From the FRx Desktop, open Row Format and click 'New'.
- Select Edit / Add Rows From Chart of Accounts.
- Add 50 or more row codes then click 'OK'. Save and exit.
- From the FRx Desktop, open Column Layout and click 'New'.
- Add 13 or more columns then click 'OK'. Save and exit.
- From the FRx Desktop, open Catalog and click 'New'.
- Enter a catalog ID and select the row and column formats created in the previous steps.
- Save the report then click 'Generate'.
- Note that error occurs.
Expected Behavior:
The report should generate without errors.
Possible Workaround:
None