"Run-time error 6: Overflow" when generating a report in FRx

Entry Type: Program Issue

Product: FRx

Application: FRx Desktop

Version Reported: 6.5.152

Status:

Resolved with Service Pack 6.5.199

Subject:

"Run-time error 6: Overflow" occurs when generating a report in FRx. This error occurs when there are more than 13 columns and 50 row codes.

Steps to Duplicate:
FRx for Sage MAS 90 and 200

  1. From the FRx Desktop, open Row Format and click 'New'.
  2. Select Edit / Add Rows From Chart of Accounts.
  3. Add 50 or more row codes then click 'OK'. Save and exit.
  4. From the FRx Desktop, open Column Layout and click 'New'.
  5. Add 13 or more columns then click 'OK'. Save and exit.
  6. From the FRx Desktop, open Catalog and click 'New'.
  7. Enter a catalog ID and select the row and column formats created in the previous steps.
  8. Save the report then click 'Generate'.
  9. Note that error occurs.

Expected Behavior:

The report should generate without errors.

Possible Workaround:

None