"Invalid path for specified work drive" in FRx
Entry Type: Informational
Product: FRx
Application: FRx
Version Reported: 6.0
Subject:
"Invalid path for specified work drive" in FRx
Possible Resolution:
The Optional Work Drive is a directory used by FRx while building GL index files. Once the index or report has been built, FRx moves the file to its proper location. The path may be changed by using either of the following methods:
From within FRx Designer:
- Open Admin / Processing Options.
- Click the arrow in the Drop-down list box for 'Optional Work Drive'.
- Browse to the desired path.
- Click 'OK'.
- Close Designer, and reopen it - the error should no longer occur.
From the FRx.ini file:
- Click the 'Start' button, then click 'Run'.
- Type frx .ini, and Click 'OK' - the file should open in Notepad.
- Locate the [Network] section.
- Change the value in the 'Work Drive' line to a valid path.
- Save and close the file.
- Launch FRx Designer and the error should no longer occur.