"Failed to load company calendar" then "Run-time error '200'. Application-defined or object-defined error" when starting FRx
Type: Informational
Product: FRx
Application: FRx Desktop
Version Reported: 6.0
Subject:
"Failed to load company calendar" and then "Run-time error '200'. Application-defined or object-defined error" appear when starting FRx.
Possible Resolution:
FRx for Sage MAS 90 and Sage MAS 200:
Fiscal Year Setup has only one year defined. To resolve:
- Delete the .g32 file in the Sysdata folder.
- Add a new fiscal year that follows the current fiscal year in General Ledger Fiscal Year Maintenance. See Fiscal Year Maintenance in Help or in the user manual for information on creating fiscal years.
Note: It may also be necessary to create one fiscal year prior to the current fiscal year. - Start FRx.
Note: FRx normally does not require multiple years.
FRx for Sage MAS 500:
Define the fiscal year:
- Expand General Ledger, Maintenance, and GL Setup. Double-click Set Up Fiscal Calendar.
- Add the year as needed.
- Click the Finish button.