"Runtime error -2147319779 (8002801d) automation error library not registered" when setting a company as default
Entry Type: Informational
Product: FRx
Application: FRx Desktop
Version Reported: 6.7
Subject:
"Runtime error -2147319779 (8002801d) automation error library not registered" occurs when setting a company as default.
Possible Resolution:
One or more of the DLL files used by FRx are not registered.
- Close all FRx applications.
- Browse to the ..\FRx\ program directory, and double-click the FRxReg.exe file. A command window displays for a few seconds and then disappears.
- Launch FRx Reporter Designer again, and set the company as default.
- If the error persists, perform the following:
-
- Close all FRx applications.
- Browse to the ..\Program Files\Common Files\System\ADO\ directory.
- Manually register the MSADOX.dll file. For more information, see How to manually register DLL files