"Runtime Error '430': Class does not support automation or does not support expected interface" in FRx

Entry Type: Informational

Product: FRx

Application: FRx Desktop

Version Reported: 6.0, 6.5, & 6.7

Subject:
"Runtime Error '430': Class does not support automation or does not support expected interface" occurs when launching an installation of FRx that resides in a different directory than the one specified when FRx was installed on the current workstation.

Possible Resolution:

In Version 6.7.x:

  1. Browse to the FRx directory.
  2. Double-click FRxreg67.cmd.

In Version 6.5.x:

  1. Browse to the FRx directory.
  2. Double-click FRxreg.exe.

In Version 6.0.x:

Register the frxlicsys.dll and frxsystem.dll files in the FRx directory. For more information, see How to manually register DLL files for FRx.