"Spec set database security does not match current FRxSys32.mdb security setting", when launching FRx
Entry Type: Informational
Product: FRx
Application: n/a
Version Reported: All
Subject:
"Spec set database security does not match current FRxSys32.mdb security setting", when launching FRx, after upgrading.
Possible Resolution:
- Select Admin / Security / Secure Companies
Note: FRx security must be active to select Security. - Choose from the following options:
a.)If the Administrator Login dialog box appears; type the password and click OK.
b.)Once logged in as the Administrator or are part of the Administrators group, the Company Security dialog box appears. - Select the company that is reference in the error and grant access to the user(s) who cannot run the report. Users could have been automatically denied access to this new company, depending on how the FRx security settings were configured.
If security was not set up in the older version of FRx:
- Select Admin / Organization / FRx Security
- Check 'Use security in FRx'
Note: if you do not have an Administrator password set up it will prompt you to set one up at this time - Close Admin / Organization
- Select Admin / Organization / FRx Security
- Uncheck 'Use security in FRx'
- Close Admin / Organization